    Development of Institutional Reference Level of Radiation Dose for Cardiac Catheterization Procedures

    Thumbnail
    View/Open
    abstract-final-fahs-online_26-26.pdf (189.8Kb)
    Date
    2023-09
    Author
    Sigera, MPII
    Ahamed, MFA
    Ramanathan, V
    Athokorala, TD
    Metadata
    Show full item record
    Abstract
    Fluoroscopy-guided interventional procedures have gained prominence in diagnostic and therapeutic settings due to their minimally invasive nature. Among these procedures, Coronary Angiogram (CAG) stands out as one of the most commonly performed cardiac interventions. To minimize patient radiation exposure, the International Commission of Radiation Protection (ICRP) recommends to establish Diagnostic Reference Levels (DRLs) nationally or regionally. This study aims to establish an institutional DRL for CAG procedures at a selected private hospital in Colombo, Sri Lanka. The research was conducted in the cardiac catheterization laboratory, focusing on 201 CAG procedures performed using two separate C-arm machines. For machine No: 01- PHILIPS ALLURA clarity FD-10, the median cumulative DAP was 9060.50 mGy.cm2 while it was 7498.00 mGy.cm2 for machine No: 02- PHILIPS AZURION 7 B20/15. These median values were considered as their respective DRLs for CAG procedures in each machine according to the ICRP recommendation. In addition to establishing the DRLs, the study identi ed signi cant correlations between patient e ective dose and several factors, including patient weight, uoroscopy time, and the number of images taken. In conclusion, this study established institutional DRLs for CAG procedures and highlights the importance of optimizing radiation dose to achieve better patient outcomes. Established DRL values for DAP were quite low compared with previous studies. Therefore, this study recommends to develop national DRLs for interventional procedures to optimize the radiation exposure level.
    URI
    http://ir.kdu.ac.lk/handle/345/6936
    Collections
    • Allied Health Sciences [70]

    Library copyright © 2017  General Sir John Kotelawala Defence University, Sri Lanka
    Contact Us | Send Feedback
     

     

    Browse

    All of IR@KDUCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsFacultyDocument TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsFacultyDocument Type

    My Account

    LoginRegister

    Library copyright © 2017  General Sir John Kotelawala Defence University, Sri Lanka
    Contact Us | Send Feedback