• Login
    • University Home
    • Library Home
    • Lib Catalogue
    • Advance Search
    View Item 
    •   KDU-Repository Home
    • INTERNATIONAL RESEARCH CONFERENCE ARTICLES (KDU IRC)
    • 2022 IRC Abstracts
    • Allied Health Sciences
    • View Item
    •   KDU-Repository Home
    • INTERNATIONAL RESEARCH CONFERENCE ARTICLES (KDU IRC)
    • 2022 IRC Abstracts
    • Allied Health Sciences
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A Comparison of ABC/2 Formula with a Semiautomated Software-Based Hematoma Volume Measurement Technique in Intracranial Haemorrhage

    Thumbnail
    View/Open
    e17f97d3a511-p-08.pdf (107.5Kb)
    Date
    2022
    Author
    Madubashini, RWMK
    Attanayake, AMTJ
    Shiron, WA
    Wickramarathne, WJC
    Wickramasinghe, WMIS
    Pallewatte, AS
    Attanayake, AMDK
    Metadata
    Show full item record
    Abstract
    Intracranial haemorrhage has been reported as a cause of all kinds of strokes while causing high mortality and disability for a longer duration and the accuracy of volumetric measurement of the hematoma has a considerable impact on the correct diagnosis and choice of treatments. This study aimed to compare a manual method and a software-based method to measure hematoma volume while evaluating changes in the mean HU value of the hematoma and the impact of the time interval between the two consecutive scans on hematoma volume using non-contrast computed tomography (NCCT) head images. The volumetric measurement of each hematoma was carried out separately using a manual method and a software-based (SB) method in 61 NCCT head images. For the manual method, TADA formula was used to estimate the hematoma volume with length, width and depth measured on NCCT axial and sagittal brain images. 3D slicer (Slicer 4.10.2) software was used for the software-based volume analysis and to measure the HU value of the hematoma. Two volume measurement methods demonstrated a significant difference between their measurements (p<0.05) with a significant strong positive correlation with each(r=0.977). Furthermore, hematoma volume difference and time interval between scans revealed a moderate positive correlation(r=0.517) and the haemoglobin level at admission demonstrated mild positive correlations with hematoma volumes (r=0.274) both of which are statistically significant. Significant mild positive correlations were found between mean HU value and the two hematoma volumes (r= 0.307, r= 0.263) respectively, whilst the mean HU difference demonstrated a moderate positive correlation with hematoma volume difference. The TADA approach demonstrated a significant difference in volume measurements when compared to a software-based method, therefore more research is needed to support the implementation of an internally designed automatic volumetric measuring method to improve accuracy and efficacy.
    URI
    http://ir.kdu.ac.lk/handle/345/6004
    Collections
    • Allied Health Sciences [59]

    Library copyright © 2017  General Sir John Kotelawala Defence University, Sri Lanka
    Contact Us | Send Feedback
     

     

    Browse

    All of KDU RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsFacultyDocument TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsFacultyDocument Type

    My Account

    LoginRegister

    Library copyright © 2017  General Sir John Kotelawala Defence University, Sri Lanka
    Contact Us | Send Feedback