Show simple item record

dc.contributor.authorWithanawasam, TI
dc.contributor.authorFernando, WAS
dc.contributor.authorUdarika, LLS
dc.date.accessioned2023-11-03T04:05:01Z
dc.date.available2023-11-03T04:05:01Z
dc.date.issued2023-09
dc.identifier.urihttp://ir.kdu.ac.lk/handle/345/6791
dc.description.abstractTransfusion service must adhere to the strict quality assurance program to ensure minimal to zero risk to the recipient and optimal therapeutic efficacy. Study is planned to assess a selected internal quality monitoring parameters of blood components produced at University Hospital, Kotelawala Defence University . The samples from all components collected and processed from March 2022 to April 2023 were tested and analyzed for Transfusion Transmitted Infection (TTI) markers. According to international standards four units of each component were selected by simple random sampling for internal quality parameters. The samples were obtained from each unit according to standard procedure and tested for specific quality parameters. Number of discard units was calculated according to the component type. 1477 Red Cell Concentrates (RCC), 1291 fresh frozen plasma and 1036 platelet concentrates have been produced. Thirteen (0.88%) unit samples were TTI screening reactive. Mean packed red cell volume was 291 ml and haemoglobin per unit was 65 g/unit. Mean haematocrit was 68% and pH was 6.9. Mean volume and count in platelet concentrates were 69 ml and 74×109 /unit respectively. White cell contamination was 0.02×109 /unit. Swirling was present in all units. Produced components met ≥ 75% of minimum standards according to the international guidelines. 27.9% of RCC supply deficit was detected. Total RCC discard was 1.28%. Implementation of standard operating procedures and validation of the instruments and techniques have been successful according to the findings. The study ensures the quality and safety of blood components as a therapeutic product.
dc.language.isoenen_US
dc.subjectBlood componentsen_US
dc.subjectInternal quality controlen_US
dc.subjectQuality assuranceen_US
dc.titleRetrospective Study on the Quality Monitoring Procedure of Blood Components in Newly Established Manufacturing Facility at the Department of Transfusion Medicine, University Hospital, General Sir John Kotelawala Defence Universityen_US
dc.typeArticle Abstracten_US
dc.identifier.facultyFaculty of Medicineen_US
dc.identifier.journal16th International Research Conferenceen_US
dc.identifier.pgnos5en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record